Measurement properties and operational feasibility of an automated arterial occlusion pressure assessment system for blood flow restriction exercise
Physiological measurement · 2026 · Vol 47(9) · 095009
Dr. Nicholas Rolnick · Co-author
Abstract
Objective. To evaluate the validity, reliability, agreement, and operational feasibility of an automated arterial occlusion pressure (AOP) assessment system compared with a manual Doppler-based assessment.
Approach. Forty healthy adults (20 men and 20 women) completed upper- and lower-limb (LL) AOP assessments using automated and MDA methods in a randomized and counterbalanced design. Concurrent validity, agreement, intraday and interday reliability, operational feasibility, perceptual responses, and procedure-related symptoms were evaluated. Exploratory analyses examined whether sex modified the difference between automated and MDA-derived AOP measurements.
Main results. MDA demonstrated good-to-excellent reliability (ICC = 0.84–0.98; CV = 1.38%–3.25%). The automated system demonstrated moderate-to-good intraday reliability (ICC = 0.74–0.85) but poor LL interday reliability (ICC = 0.36). Compared with MDA, automated AOP showed systematic bias and wide limits of agreement. No evidence of a sex-related difference in the between-method discrepancy was observed for either upper- or LL AOP. Although automated assessment reduced testing time by 81.9%–86.7%, frequent upper-limb (UL) measurement failures reduced the automated measurement success rate to approximately 57%, substantially increasing adjusted assessment time and limiting operational feasibility, while discomfort and affective responses were more favorable than with MDA.
Significance. The automated AOP system improved assessment efficiency and participant experience but demonstrated less favorable reliability estimates, limited agreement, and frequent upper-limb measurement failures. Consequently, automated and MDA should not be considered interchangeable for individualized AOP prescription.
Authors
Joanderson Felipe Soares Silva, Nicholas Rolnick, Maria Luiza Araujo Cerqueira, Gabriela Mota Pinto Silva, Rafael Pereira, Mikhail Santos Cerqueira
Dr. Nicholas Rolnick’s contribution: Co-author
Keywords
- Rehabilitation
- Validity
- reliability
- Resistance Training
Read the full paper
Cite this paper
Joanderson Felipe Soares Silva, Nicholas Rolnick, Maria Luiza Araujo Cerqueira, Gabriela Mota Pinto Silva, Rafael Pereira, Mikhail Santos Cerqueira. (2026). Measurement properties and operational feasibility of an automated arterial occlusion pressure assessment system for blood flow restriction exercise. Physiological measurement, 47(9), 095009. https://doi.org/10.1088/1361-6579/aea9ed
Related research
More from this line of work
Journal article · 2026
Validity, tolerability, and feasibility of automated arterial occlusion pressure across body positions
Read the record
Journal article · 2023
Reliability and Validity of a Portable Traction Dynamometer in Knee-Strength Extension Tests: An Isometric Strength Assessment in Recreationally Active Men
Read the record
Letter / commentary · 2026
Are we comparing blood flow restriction outcomes using equivalent equipment? The importance of empirically validated equipment and accurate reporting for comparison of outcomes related to safety and efficacy
Read the record
Apply the research
From the paper to the patient
Every protocol in The Complete BFR Certification cites the literature it came from, including this line of work. The module-by-module bibliography (Bonus 5) maps each claim back to its paper.

